Automatic Capacitor Controller

  • Automatic Capacitor Controller
Key attributes
Brand Rw Energy
Model NO. Automatic Capacitor Controller
Rated voltage 110V
Methods of output Switching quantity
Output Voltage 250V
Output current 20A
communication protocol DNP3.0 TCP/IP
Series IntelliCap® 2000
Product descriptions from the supplier
Description

IntelliCap 2000 Automatic Capacitor Controls are specifically designed to control pole-mounted and pad-mounted switched capacitor banks in electric distribution systems to regulate reactive power or line voltage. These reliable, easy-to-use, microprocessorbased controls normally operate autonomously based on the control strategy selected.

With a one-way communication device installed, an IntelliCap 2000 control can also operate in response to switching commands from SCADA or other centralized control. With a two-way communication device installed, local status information and feeder data are additionally available remotely. Remote configuration also is possible.

IntelliCap 2000 controls are superior to other two-way communicating capacitor controls, which only operate in response to centralized control commands based on measurements at the substation. With the normal stand-alone operation of IntelliCap 2000 controls:

  • A communication problem won’t compromise VAR support.
  •  A problem at one capacitor bank won’t affect other capacitor banks.
  • Multiple contingencies are handled automatically.
  • System changes and expansion don’t require extensive reprogramming.

Provide a Full Range of Automatic Functions

IntelliCap 2000 controls offer a wide range of software-selectable functions, including:

  •  Voltage, time, temperature, time-biased voltage, and time-biased temperature control strategies (VAR and current control strategies are optionally available.)
  • Voltage/temperature and SCADA override strategies (When enabled, the control returns to its regular control strategy after receiving a SCADA command.)
  • Automatic calculation of voltage change (and kvar change, if applicable) due to capacitor bank switching
  • Automatic adjustment for daylight savings time and holidays
  • A daily limit on automatic switching operations

Undervoltage and overvoltage protection Neutral input sensing is optionally available and can lock out the capacitor bank if blown fuses or stuck switch poles are detected.

FAQ
Q: What is the function of capacitor switch?
A:

 The main function is to adjust reactive power. When the reactive power is insufficient in the power grid, the switch will put the capacitor in to compensate the reactive power, improve the power factor, improve the power quality, and reduce the line loss. When the reactive power is in excess, the capacitor can be removed.

Q: Can this device be connected to SCADA System or DMS?
A:

This device can connect to SCADA System and DMS, and you can connect the terminal to the server according to your local network conditions. This terminal supports CDMA (3G)/LTE (4G)/ NR(5G), ETH, fiber optic and other ways to access the network. You can also contact us directly, and we will provide you with a solution for distribution network automation.

Q: What should I pay attention to when using capacitor switch?
A:

It should be noted that the switching frequency cannot be too high to avoid damage caused by frequent action of the capacitor. At the same time, it is necessary to reasonably choose switching according to the actual situation of the power grid

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
Chat
Manager