DC12 to 40.5kV Short-Circuit Current Limiter

  • DC12 to 40.5kV Short-Circuit Current Limiter
  • DC12 to 40.5kV Short-Circuit Current Limiter
Key attributes
Brand Rw Energy
Model NO. DC12 to 40.5kV Short-Circuit Current Limiter
Rated voltage 15kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series DDX1-DC
Product descriptions from the supplier
Description

Product Introduction

The DC Short-Circuit Current Limiter shares the same fast-acting mode and interruption principle as the DDX1 AC product: it limits and interrupts the short-circuit current before the instantaneous value of the short-circuit current rises to the expected peak. The maximum instantaneous value of the actual short-circuit current is much lower than the peak value of the first major half-cycle of the short-circuit current, providing an economical and reasonable short-circuit current solution for DC users in power systems.

Its differences from the AC product lie in three aspects: (1) Sensor; (2) Electronic controller; (3) Fuse.

Product Features & Advantages

  • Fast interruption speed (high-speed): The entire interruption time is less than 10ms.

  • Distinct current-limiting characteristic during interruption (current-limiting): Effectively restricts fault current peaks.

  • Versatile application scenarios: Suitable for both indoor and outdoor use; can be used independently or integrated into switchgear cabinets as a complete set.

Main technical parameters

serial number

Parameter Name

unit

Technical parameters

1

Rated voltage

kV

12-40.5

2

Rated current

A

630-6300

3

Rated expected short-circuit breaking current

kA

50-200

4

Current limit coefficient = cut-off current / expected short-circuit current peak

%

15~50

5

Insulation level

Power frequency withstand pressure

       kV/1min

42-95

Lightning impact withstand pressure

            kV

75-185

Product Usage

  • Protection of DC transmission and distribution systems

  • Fast protection of DC system cables, power electronics

FAQ
Q: Is it compatible with existing communication FCL technology?
A:

The core current limiting principle is similar, but the control logic and arc extinguishing structure are optimized for DC characteristics and cannot be directly interchanged.

Q: What is the difference between DC current limiting and AC current limiting?
A:

DC has no natural zero crossing point, making it more difficult to disconnect. This product adopts high-speed mechanical and power electronic composite technology to ensure reliable current limiting and cutting off within a few milliseconds.

Q:  Can this product be used for DC systems?
A:

Yes, specifically designed for DC 12kV to 40.5kV systems, solving the problem of short-circuit current limitation in DC scenarios such as photovoltaics, energy storage, and rail transit.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
Chat
Manager