| Brand | Rw Energy |
| Model NO. | 60KW Vehicle DC Fast Charger |
| Rated Output Rating | 60kW |
| Output Voltage | DC 200-1000V |
| Max Output Current | 200A |
| Power Conversion Efficiency | ≥95% |
| Connector Options | CCS2+CCS2 |
| Cable Length | 5m |
| Input Voltage | 380V |
| Series | WZ05 |
Description
This DC fast charging station supports mainstream charging standards including CCS1, CCS2, CHAdeMO, GBT, and Tesla, allowing flexible customization and combination to achieve full compatibility with all electric vehicle brands. Whether it's CCS fast-charging models in the European and American markets, Japanese CHAdeMO protocol vehicles, Chinese GBT standard vehicles, or Tesla's entire lineup, all can be charged instantly upon plugging in.
Key Features
Multi-Standard Compatibility: Resolves charging interface differences across brands and regions in one go, eliminating the need for additional adapters.
Flexible Customization: Supports free combination of single or multiple standard modules to suit diverse scenarios such as commercial operations, highway rest areas, and community charging stations.
High-Efficiency Fast Charging: With a maximum output power of 60kW, it can charge a vehicle from 10% to 80% in just 30 minutes.
Intelligent Management: Integrated smart monitoring system for real-time tracking of charging status, power distribution, and device health, supporting remote operation and maintenance.
Safe & Reliable: Equipped with overvoltage/overcurrent protection, leakage monitoring, and temperature control systems to ensure safe and stable charging throughout the process.
Technical Parameters
Category |
specifications |
Data parameters |
|
Product Model |
WZ05-60kW |
WZ05-80kW |
|
Appearance structure |
Dimensions (L x D x H) |
600mm x 700mm x 1870mm |
|
Weight |
360kg |
||
Length of charging cable |
5m |
||
Connectors |
GBT,CCS2,CCS1,CHAdeMO,NACS |
||
Electrical indicators |
Input Voltage |
400VAC / 480VAC (3P+N+PE) |
|
Input frequency |
50/60Hz |
||
Output Voltage |
200 - 1000VDC |
||
Output current |
0-200A |
||
rated power |
60kW |
80kW |
|
Efficiency |
Peak Power≥96% |
||
Power factor |
>0.98 |
||
Communication protocol |
OCPP,State Grid Corporation of China,YKC, Xiao ju and other operating platforms. |
||
functional design |
Display |
7inch LCD with touch screen |
|
Number of guns |
2 |
||
Access Control |
RFID/ ISO/IEC 14443A/B / POS machine (Optional) |
||
Communication |
WIFI/Ethernet / 3G/4G Modem (Optional) |
||
Power Electronics Cooling |
Air Cooled |
||
work environment |
Operating temperature |
-30°C to 75C |
|
Working/Storage Humidity |
≤95% RH / ≤ 99% RH (Non-condensing) |
||
Altitude |
< 2000m |
||
Ingress Protection |
IP54 || IK10 |
||
safety design |
Safety protection |
Overvoltage protection, lightning protection, overcurrent protection, leakage protection, waterproof protection, etc |
|
Emergency Stop |
Emergency Stop Button Disables Output Power |
||
Dimension

Is the DC fast charging station a specific implementation of leakage protection?
Specific implementation of leakage protection:
Hardware level:Residual current device: Install a residual current device inside the charging station. When the leakage current detected exceeds the set threshold, the power supply is automatically cut off.
Current transformer: Install a current transformer inside the charging cable or charger to monitor current changes in real time. Once abnormal current is detected, the protection action is triggered.
Ground fault protection: Integrate a GFCI inside the charging station to detect ground faults and cut off the power supply.
Software level:
Fault detection algorithm: Monitor the change of current through software algorithms. When abnormal current is detected, the system will issue an alarm and cut off the power supply.
Real-time monitoring: Monitor parameters such as current and voltage during the charging process in real time. Once an abnormality is found, protection measures are taken.
Application Scenarios
Residential community centralized charging station: Adapt to daily community energy replenishment and customize module combinations according to parking spaces. Full protocol compatibility solves interface issues, intelligent system facilitates property operation and maintenance, multiple protections ensure safety, and air-cooled design simplifies installation and maintenance.
New Energy Vehicle 4S Store and Maintenance Service Center: Used for 4S dealership car exhibitions, test drive car energy replenishment, and maintenance inspections. Fully compatible features reduce device costs, efficient fast charging ensures test drive circulation, supports multi protocol docking with store systems, and can expand paid value-added services.
Fast Charging Stations in Logistics Parks and Freight Distribution Centers: Adapt to centralized energy replenishment in logistics parks, quickly replenish 60-80kW power, and improve efficiency with dual guns. IP54 protection and wide temperature adaptation to cope with complex environments, multiple protections and intelligent scheduling ensure stable operation.
1. Only as an additional service, not for profit purposes: For scenarios such as hotels/homestays, beauty salons, etc., it is recommended to use a light asset model and deploy a small amount of WZ15L, WZ15W, or WZ17W for charging settlement through local pricing models, in order to provide additional value-added services.
2. Scenarios for small commercial charging stations/shopping mall charging stations: Considering the load capacity of the station area, it is not possible to deploy too many charging positions. WZ05, WZ06, WZ07, WZ08, and other fast charging devices with one machine and two guns can be selected, which are the preferred choices for the renovation of old parking lots. They can be easily deployed and used. If you need a scenario with one machine and multiple positions, you can choose the WZ09 and WZ10 series.
3. Medium to large commercial charging station scenarios: Choose multiple integrated one machine dual gun high-power solutions, such as WZ06, WZ07, WZ08, WZ09, WZ10 series, or a set of WZ12 series, to meet the simultaneous charging of multiple vehicles.
4. Large and ultra large commercial charging scenarios: Choose the WZ12 series, equipped with a large number of fast charging terminals and a small number of liquid cooled charging terminals. Firstly, it can meet the ultra fast charging needs of some high-end car models, demonstrating operational strength and improving reputation. Secondly, it can meet the simultaneous charging needs of many vehicles through a large number of fast charging terminals.
The entire system supports intelligent power regulation, which can dynamically allocate power based on grid load and battery status, avoiding grid overload and reducing operating costs.
RFID card swiping is standard across the entire range (ISO/IEC 14443A/B); All products in the series that support the OCPP 1.6 protocol can be integrated with commercial platforms to meet operational needs.