占位边距

APView500 power analyzer with ModBus-RTU communication protocol

  • APView500 power analyzer with ModBus-RTU communication protocol

Key attributes

Brand Rw Energy
Model NO. APView500 power analyzer with ModBus-RTU communication protocol
Rated frequency 50/60Hz
Series APView

Description

  General

Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques –Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips/swells/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control. It meets IEC 61000-4-30 Class A Edition 3.1 with respect to standardization of power quality index measurement methods, measurement accuracy of index parameters, clock synchronization, event alarms and others and satisfy the demands of power quality monitoring of power supply system up to 110kV. Therefore, it is widely applicable for power quality monitoring in chemical industry, steel industry, metallurgy industry, hospitals, data centers, transportation, construction industry and other industries.

  Parameters

  Technical Datasheet

Technical Parameter

Value

Rated Value

AC voltage:AC/DC220V, AC/DC110V or DC48V

AC current:AC1A,5A;

Overload capacity

1.2In, continuous working

20 times for 1 second

 

power supply

Rated: AC/DC220, AC/DC110V or DC48V

Permissible deviation: -20%-+20%

Power consumption:≤15W

Power Consumption

≤0.5VA (single phase)

Measuring rage

0-1.2In

Digital output

Mechanical service life: ≥10000

Output mode: Passive contacts

Switching capacity: ≤4000W or ≤384VA

On-state current: ≥16A(AC250V/DC24V) in the continuous mode;

≥30A for a short term (200ms)

 

 

 

 

 

Accuracy

Class 0.5

RMS Voltage:±0.1%

RMS Current:±0.1%

P,Q,S:±0.2%

Power factor:Class 0.5

Voltage deviation:0.1%

Frequency deviation:±0.001Hz

 

Communication

RS485,Modbus-RTU protocol;Ethernet.

Three phase unbalance

Voltage unbalance:±0.15%

Current unbalance:±1%

Power frequency withstand voltage

Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS)

Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV

Temperature

Operation: -10℃~+55℃Storage: -30℃-+80℃

Humidity

≤95%RH,no condensation,without corrosive gas

Altitude

≤ 2500m

 Dimension

 Installation

Wiring

 Network

 

Solutions for power analyzer

  • Solution for Power Quality - Detailed Explanation of Hybrid Reactive Power Compensation
    The hybrid reactive power compensation scheme (SVG+intelligent capacitor) is an economical and efficient combination of "dynamic+steady-state" compensation. The core is to use intelligent capacitors to undertake most of the basic reactive power compensation, while allowing SVG to focus on handling the rapidly fluctuating parts, thereby achieving the best balance between performance and cost. The key to the stable operation of the system lies in coordinated control, which adopts a strategy of div
  • Detailed Explanation of Capacitor-based Terminal Voltage Regulation Device
    Capacitor-based terminal voltage regulation device is a cost-effective solution to fix the low voltage issue at the end of long transmission lines.Core Principle: Connect capacitor banks in parallel at the end of distribution lines to supply capacitive reactive power, which offsets the inductive reactive power transmitted on the lines. This can greatly cut down the voltage loss caused by line reactance and directly boost the terminal voltage.Device Composition: The mainstream type now is auto-sw
  • Detailed Solution for Reactive Power Compensation with High-Capacity Collection and Low-Capacity Compensation
    1. Scheme IntroductionIn the current electrical industry, SVG is widely adopted for reactive power compensation in high‑voltage electrical systems such as 6kV, 10kV, 20kV and 35kV. Two compensation topologies are commonly used: direct grid‑connection type and transformer step‑up type.For applications with relatively small compensation capacity, the transformer step‑up SVG scheme is more cost‑effective and thus widely applied. This scheme was developed to address low power factor in high‑voltage

Documentation Resource Library power analyzer

6 to 35kV Static Var Generator(SVG) Brochure
Restricted.
6 to 35kV Static Var Generator(SVG) Brochure
Brochure
English
PDF
PDF
Power compensation equipment SVG/FC/APF Catalog
Restricted.
Power compensation equipment SVG/FC/APF Catalog
Catalogue
English
PDF
PDF
6 to 35kV Liquid-Cooled high performance SVG
Public.
6 to 35kV Liquid-Cooled high performance SVG
Operating Instruction
English
RWSVG Series Dynamic Reactive Power Compensation Device
Restricted.
RWSVG Series Dynamic Reactive Power Compensation Device
Operating Instruction
English
PDF
PDF

FAQ for power analyzer

How to transfer data to the computer?

RS485 Modbus RTU and Ethernet communication, directly connected to a computer or PLC. The supporting software allows real-time viewing of waveforms, recording of data, and generation of reports. No need to dismantle equipment, remote monitoring is extremely convenient, and it is the preferred choice for large enterprises.

Can multiple phases be measured simultaneously?

All three-phase four wire or three-phase three wire can be measured, and the A/B/C three-phase parameters are clear at a glance. Being able to analyze imbalance, I am an expert in "power health checks" for factories and data centers, and can handle comprehensive monitoring with just one meter.

Is the accuracy of power analysis high?

Compliant with IEC 61000-4-30 Class A standard, voltage/current accuracy ± 0.1%, power ± 0.2%. Being able to analyze harmonics, voltage dips, and flicker, with data accurate to three decimal places, is the "gold standard" for power quality monitoring.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Chat
Manager
WhatsApp
WhatsApp