占位边距

Intelligent Dual Power Controller

  • Intelligent Dual Power Controller
  • Intelligent Dual Power Controller

Key attributes

Brand Rw Energy
Model NO. Intelligent Dual Power Controller
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Series RWD-LC

Description

Description

With the development of society, people have higher and higher requirements for power supply reliability. In many cases, two power supplies are used to ensure the reliability of power supply, which requires a product to switch reliably between two power supplies. The intelligent dual power automatic conversion device produced by our company is mainly composed of a high-voltage vacuum circuit breaker with electric dual isolation and a dual power intelligent backup self-input controller. Applied to AC 50HZ, rated voltage 12KV, rated current up to 1250A dual power supply system, when one power failure or undervoltage occurs, the isolation switch automatically switches to the other, the whole process automatically switches to the other normal power supply. Reliable guarantee of continuity of power supply

The controller has a variety of protection functions such as short circuit, three-stage overcurrent, single-phase ground, undervoltage, reclosing and prepaid, which effectively avoids unnecessary re-supply shock when the load fails. When the common power supply fails, the switching device can automatically switch with the standby power supply to ensure reliability and safety. It is especially suitable for important places where power is not allowed, as an important electrical control device to ensure continuous power supply, it is a self-throwing self-restoring dual power automatic switching device matching with high voltage vacuum circuit breaker. The products are widely used in 10kV distribution lines in oil fields and mines, and 10kV lines in industrial and mining enterprises to ensure real-time power supply of important loads. It has the characteristics of small footprint, small investment, convenient debugging and maintenance, and is an ideal switchgear for realizing power supply automation.

Support communication methods: wireless (GSM/GPRS/CDMA), Ethernet, WIFI, optical fiber, power carrier, RS232/485,RJ45, etc., and can access other station equipment (such as TTU, FTU, DTU, etc.).

Main function introduction

1. Protection relay functions:

AST    Double line Protection,

49     Thermal Overload (Over load), 

50 Three-section of Overcurrent (Ph.OC),

50G/N/SEF Sensitive Earth Fault (SEF),

27/59 Under/Over Voltage (Ph.OV/Ph.UV), 

51C Cold load pickup (Cold load).

2. Supervision functions:

60CTS CT Supervision,

60VTS VT Supervision. 

3. Control functions:

79 Auto Reclose,

86 Lockout>>>>>>.

circuit-breaker control.

4. Monitoring Functions: 

1) Primary currents for Phases and Zero sequence current,

2) Primary PT Voltage,

3) Frequency,

4) Binary Input/Output status, 

5) Trip circuit healthy/failure,

6) Time and date,

7) Fault records,

8) Event records.

5. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands

Technology parameters

Category Item Specification
Model & System Model RWD-LCN-SP
  Version V2.3.1
  Type of operating mechanism Spring mechanism type
  System language Chinese Simplified
  PC software language Chinese Simplified, English
Power Parameters Rated working voltage 230V ±20%
  Rated frequency 50Hz/60Hz
  Electric energy consumption ≤5W
Analog Parameters Current transform quantity 6 phase current + 2 earth current
  Rated current in 5A or 1A
  Voltage transform quantity 2 voltage transform
  Voltage transform Nominal 40...120 Vrms
  Voltage sensor quantity 1 Zero Phase Sequence Voltage (optional)
  Voltage sensor Nominal 0...60 Vrms
Protection Relay & Measurement Accuracy Current protection (secondary side) 0.05~50A, ≤±3%
  Zero-sequence current protection (secondary side) 0.02~10A, ≤±1%
  Voltage measurement accuracy 10~280V, ≤±5%
Protection Performance Parameters Event resolution 2ms
  Quick-break export time Under the input of 1.2In magnification, the whole group action time is less than 40ms
  Protect export time error ≤1%
Switching Value Parameters Number of DI group1 interfaces 2COM&7DI
  DI group1 Rated voltage DC24V
  DI group1 current consumption ≤2mA
  Switching value resolution Minimum 2ms
  Number of DO group1 interfaces 2 groups NO
  DO group1 Rated voltage 230VAC/30VDC
  DO group1 Rated current 30A
Communication I/O Parameters RS485/RS232 port (optional) 1DB9 10Mbps or 1DB9 120Mbps
  Update port 1*RJ45 10Mbps
EMC Technology Parameters Insulation resistance ≥10MΩ
  Voltage mutation 100%, 0.5s
  High-frequency interference (series mode) 1.5kVP, 1min
  High-frequency interference (common mode) 2.5kVP, 1min
  Transient pulse 4.0kVP, 1min
  Inrush current interference 4.0kVP, 1.2/50μs
  Electrostatic discharge 8kV
  Power frequency magnetic fields 100A/m
  Damping oscillating magnetic field 100A/m
  Power frequency withstand voltage 2.5kV, 1min
  Lightning rush voltage 5kV, 1.2/50μs
  Enforce standards DL/T 721-2000 class IV
Working Environment Parameters Ambient temperature -25℃ ~ +70℃
  Storing temperature -40℃ ~ +70℃
  Ambient humidity 5% ~ 100% (Non-congealing cream)
  Rate of ambient temperature change <25℃/h
  Altitude range -100~3000m
Machine Case Parameters Weight >6kg
  Size 450&times;350&times;245mm
  Class of protection IP55

 

Device structure

RWD-LC-尺寸.png

双电源控制器的应用方案.png

About customization

The following optional functions are available: Upgrade SMS Function. Upgrade RS485/RS232 socket.

For detailed customization, please contact the salesman.

Q: What is a high voltage dual power switch?

A: The high-voltage dual power switch is a device used to automatically switch between two high-voltage power supplies. When one power supply fails (such as power failure, abnormal voltage, etc.), it can quickly switch the load to another normal power supply to ensure the continuity of power supply.

Q: Where is it mainly used?

A: In hospitals, data centers, large factories and other places where continuity of power supply is highly required. For example, during hospital surgery, a sudden power outage may endanger the patient's life, and the use of high-voltage dual power switch can avoid this situation.

Q: How fast does it switch?

A: Generally speaking, the switching time can reach the millisecond level, which can minimize the time of load power failure and avoid damage to the equipment.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
Chat
Manager
WhatsApp
WhatsApp